VIBRATION EQUIPMENT

acceleration converters
VPI-057 acceleration; a; 0,5-100 pC/m/s2; to 1000 (14000) Hz; +120 °C.
VPI-061 acceleration; a; 0,5-100 pC/m/s2; to 1000 (14000) Hz; +120 °C.
VPI-103-Q acceleration; a; 2,0 pC/m/s2; to 3000 m/s2; 2000 pF; to 5000 Hz; +250 °C.
VPE-080 acceleration; a; 10 mV/m/s2; to 150 (300) m/s2; to 6000 Hz; +250 °C.
VPI-081-Q0,3 acceleration; a; 0,3-0,4 pC/m/s2; to 500 m/s2; 600 pF; to 1000 Hz; +400 °C.
VPE-078; VPE-079; VPE-089; VPE-086 acceleration; a; 10 mkA/m/s2 (mV/m/s2) ± 5 %; to 100 m/s2; to 1000 Hz; +120 °C.
VPI-218-K; VPI-217-K; VPE-157-K control acceleration converters.
velocity converters
VPE/FSA velocity; v; VPE-079 to +120 °C; VPE-080 to +250 °C; FSA-088 to +70 °C; output 1; velocity; to 16 (32, 64, 96) mm/s; 4 .. 20 mA; 10 .. 1000 Hz; diagnostics. output 2; velocity RMS; to 16 (32, 64, 96) mm/s; 4 .. 20 mA; 10 .. 1000 Hz.
VPE-083-T; (VPE-085-T) velocity; v; RMS; to 16 (32, 64, 96) mm/s; 4 .. 20 mA; 10 .. 1000 Hz; to +80 °C.
displacement and vibration displacement converters P/FSP
P/FSP P - Proximeter 180 °C; FSP - Converter 70 °C. output 1; displacement М10 - 2 mm; М16 – 5 mm; М20 – 6 mm; М24 – 8 mm; 4 .. 20 mA. vibration displacement AC from 25 to 500 mkm (for М10); 5 .. 500 Hz; output 2; (for М10) p-p of vibration displacement DC RMS from 25 to 500 mkm; 4 .. 20 mA; 5 .. 500 Hz;
tachometer and displacement converters P/FST
P/FST P - Eddy-current converter 180 °C; FST - Converter 70 °C. output 1; displacement М10 - 2 mm; М16 – 5 mm; М20 – 6 mm; М24 – 8 mm; 4 .. 20 mA. output 2; control surface - gear, groove, key; pulse frequency 1..4000 Hz.
displacement converters K/FSM
K/FSM K - Displacement converter 180 °C; FSM - Converter 70 °C. output «displacement» 4 .. 20 mA; width of the "ridge", mm 10; 20; 25; 30; 35; 40 displecement measurement range, S, mm; 0-50; 0-45; 0-40; 0-35; 0-12.
displacement converter of safety striker K/FSB
K/FSB K - Eddy-current converter 180 °C; FSB - Converter 70 °C. output «displacement» 4 .. 20 mA; striker diameter 20 (26) mm; measuring displacement 6 mm, relay switching delay time 0,5 s.
calibration devices
ILP-160 linear displacement meter.
IPD-177 two-axis linear displacement meter.
KV-184 calibration device for vibration converters.
PR mounting of converters
system of vibration control
SKV-K1 vibration monitoring system; vibration speed; set point A/B, B/C, C/D; disconnection at set point C/D.
SKVT video
publications and certificates
Piezosensor. Stages of formation.
Single-channel control system SKV-K1.
Vibro-calibration complex VKK-128.
Vibro transducers with built-in electronics
Optimization of the characteristics of a piezoelectric low-frequency type vibrator VPN-1.
Vibrometers with digital correction frequency response, linearity.
Diffusion welding of high-temperature piezoceramics based on bismuth titanate with a heat-resistant alloy.
Investigation of the transition zone of a high-temperature piezoceramic compound with a metal.
Method for evaluating the strength of a metal-piezoceramic bimorph construction when it is manufactured by diffusion welding.
Providing mechanical strength of welded metal-ceramic construction.
Accuracy when measuring the vibration vector along three mutually perpendicular measuring axes.
Vibro-measuring complex VPE-078 / FSA-088.
Patent accelerometer.
Certificate of explosion protection of electrical equipment 2013.
TU "Vibro-measuring complex KV ..."
Certificate of measuring equipment type 2016.
Type-examination Certificate 2020 Velomitors.
Type-examination Certificate 2020 Proximitors.
Catalog 2022